Feature:
Delay time range: 0.1 seconds minimum, up to 999 minutes adjustable.
Output capacity: can control within 30v5A DC or within 220v5A AC equipment
Quiescent current: 20mA
Working current: 50mA
Life: >100,000 times
Working temperature: -40°C to 85°C
Size: 64.2mm * 34.8mm * 18.5mm
Function:
P-1: The signal triggers the relay to pull in, when the time is up, the relay is off, during the delay
A: Re-trigger invalid B: Re-trigger timing again C: Re-trigger relay reset finish timing
P-2: Signal triggering starts counting time T1, when time reaches the relay pull-in, time T2 is off (reset)
A: Re-trigger invalid B: Trigger again re-count C: Do not need to trigger the power to start the delay
P-3: Recycling use: Turn on T1, Disconnect T2, Endless cycle. T1 and T2, the time is adjustable
If you connect or disconnect a parameter to 0, can achieve power-on delay or power delay, power off does not cycle
A: After power on, the relay immediately energized B: After the relay is energized, the relay is turned off and then ON again
P-4: Have signal, the relay is pull in and keep, when the signal disappears, the timer starts. When the time is up, the relay is off. During the delay time, the signal is again given, the delay is canceled, the relay is kept, the signal disappears and the time is re-counted.
Key Settings Description:
K1: Function selection key: long press K1 key for 2 seconds, appear P *, short press K1 to select mode, press K2 to enter mode
K2: Shift key: Press to adjust the flashing position of digital tube, which digital tube flashes, K3 will adjust the value of flashing digital tube. Until you press K2, digital tube no longer flashing,  time setting is complete, automatically save the set time and power-off memory
K3: Digital tube flashing: K3 adjust the digital changes, 0 to 9 followed by changes.
When the digital tube display is normal: K3 adjust the decimal point position, the decimal point in the first digit means from 0 to 999 minutes; in the tens digit means 0 to 99.9 seconds; no decimal point means 0 to 999 seconds
Note 1: After selecting the working mode, short press K1 to enter the function of A, B, C switching, the digital tube will not display A or B or C, only after short press K1 to trigger signal , then it will default display A
Note 2: Function P-2 and P-3 have two groups of time to be adjusted, press K2 six times for one group, the first three times to adjust one time, and another three times for the second time. (Blue LED light indicates the pull-in of relay time and blue LED light indicates the disconnect time of setting relay.)
Package includes:
1 x Relay module

Selection: After power on, long press K1 2 seconds later into the select function mode, P1-1 to P1-4for choose.
P1-1 operating modes:a signal to trigger relay, time is up, the relay disconnect users. You can set relay time T, click K2 the hundred digital tube starts flashing, then press K3, the hundred digital change. Click K2
ten digital tube starts flashing, then press K3, ten digit changes. Click K2 bit digital tube starts flashing, then press K3, single-digit change. Then click K2, digital pipe does not blink, then press the K3, shifting the decimal point, the decimal point in a bit indicates 0-999 minutes in ten represents 0 to 99.9 seconds without decimal point represents 0-999 seconds. Good choice, bringing the time setting is completed. Short press
K1, enter function off line-tuning settings, trigger the default delay period is invalid, press K1, during the delay trigger active(re-timing), click on the K1, during the delay reset (timer turned off, the relay reset) press
again to repeat the default settings for the first time.
P1-2 operating modes: A signal trigger ,digital countdown begins, X seconds after, there lay open Y seconds, then close. Users can set the relay time X,Y. P1-1 different time settings similar to the blue lights that set
the relay time, blue light indicates setting relay off time. Short press K1, enter function offine-tuning the set, the default trigger is invalid during the delay, press K1, during the delay trigger active(re-timing), then click
the first repeat default settings.
P1-3 operating modes: Open X seconds, disconnect Y seconds, infinite loop.Users can set the relay time X,Y. Time setting similar to P1-2. Short press K1, enter function off line-tuning set. The default function is: set up
an electric circuit the relay first open, press the K1, there lay first close.Press again to repeat the default functionality.
P1-4 operating modes:a signal to trigger the relay open but do not start the timer, when the trigger signal disappears, digital count down begins, X time after, the relay close. During the delay, again to the signal, digital count down canceled, stays energized, the signal disappears, restart count down. (equivalent to release the button to start timing, commonly usedi n power-off delay). Users can set the relay time X; time setting similar to P1-1.

 

 

 